Wed Aug 29, 2012 7:19 pm by mdc5150
So we have a big job tomorrow rekeying a bunch of county buildings and they use Schlage I/C cores on most of what they have. They told us today that there are several that they do not have any keys for. I have tried bumping these things to control before and I've never been successful and picking them to control has not worked either. So talking with the guy at work this is what we came up with. I wish I could say I thought of it by myself but it was a team effort.
What you see in the picture is a control key cut down to the lowest possible depth all the way down to the control space. Right behind the control space I cut the key in two. What you do is put the tip in, feed it with the other part which is the perfect length, remove the larger part and pick the lock as normal. It works very well in the shop and I am hoping that tomorrow it goes as well.
You do not have the required permissions to view the files attached to this post.
Last edited by